Earth Support Corp
On site now

Earth Support · Cambridge

Soldier Pile & Lagging Wall, 44 Russell St

Five new homes with basements are going in on a Cambridge lot, and the excavation runs along a side lot line with a three-story house about 3 ft beyond it. The ground is sand over soft marine clay, and groundwater sits 10–11 ft down, about at the bottom of the cut.

1234567
Schematic — illustrative, not for construction; pending PE review.

The problem

Five new homes with basements are going in on a Cambridge lot, and the excavation runs along a side lot line with a three-story house about 3 ft beyond it. The ground is sand over soft marine clay, and groundwater sits 10–11 ft down, about at the bottom of the cut.

The engineered approach

Eighteen HP12x53 soldier piles, each up to 20 ft long, go into 24 in drilled holes at 4 ft centers along about 68 lf of wall, with lean concrete around the embedded length and flowable fill above. The piles are drilled rather than driven to keep vibration away from the neighbors, and timber lagging goes in between the flanges as the builder digs down in lifts of no more than 4 ft. The wall is a cantilever, with no tiebacks or bracing.

Where it stands

  • Underway now: one lot-line wall, 18 soldier piles
  • Drilled, not driven, beside a three-story neighbor
  • Cantilevered: nothing anchored under the neighbor's lot

How we're building it

A schematic section of the earth support system for this Cambridge job. Scroll to build it in construction order, or select a callout to read the detail.

Schematic cross-section of the cantilever soldier pile and timber lagging wall on the side lot line at 44 Russell St, Cambridge: an HP12x53 pile up to 20 ft long in a 24 in drilled hole, lean concrete around its embedded length and flowable fill above, lagged between its flanges as the cut goes down, with the neighbor's three-story house about 3 ft beyond the line.An illustrative section through the soldier pile and lagging wall Earth Support is installing on a side lot line at 44 Russell Street in Cambridge, where five new homes with basements are being built; the work is underway. On the right, about 3 feet beyond the wall line, is the neighbor's three-story house, drawn cropped at the top. On the left is the excavation for the new homes, by others. In construction order: a 24 inch hole is drilled at the wall line, rather than a pile being driven, to keep vibration away from the neighboring houses; a steel HP12x53 H-pile up to 20 feet long is set in it; lean concrete fills the hole around the embedded length of the pile and excavatable flowable fill fills it above; then the builder excavates in lifts of no more than 4 feet while Earth Support places 3 inch timber lagging between the pile flanges as each lift opens. There are no tiebacks, no bracing and no wales: each pile works as a cantilever, held by the length embedded below the bottom of the cut. An inset at top left shows the wall in elevation from the excavation: 18 piles at 4 foot centers along about 68 linear feet, with lagging spanning between them from grade down to the cut and the embedded lengths of the piles dashed below it. The cut is dimensioned as up to 10 feet, which was the basis of Earth Support's quote; it is not an as-built measurement. The ground, from the project geotechnical summary with two borings to 47 feet, is about 2 feet of fill and subsoil over medium dense stratified sand to 16 to 21 feet, a thin stiff silt and clay crust, then soft marine clay, with no till or rock to 47 feet. Groundwater is 10 to 11 feet below grade, about at the bottom of the cut, shown with a water-table mark on the neighbor's side; on the excavation side a ghosted dashed line shows the dewatering by others holding the water at least 1 foot below the cut. Drawn ghosted and dashed, because they are by others, are the excavation, the dewatering and the new home, whose footing, foundation wall and slabs sit in the cut on the left. Schematic only: apart from the pile length, the pile count, spacing and wall length, and the cut basis, sizes are not to scale; pending professional-engineer review.Fill & subsoilStratified sandSilt & clay crustSoft marine clay
Schematic — illustrative, not for construction; pending PE review.

Callouts

Select a numbered part below to read what it is and what it does.

Ready to scope your foundation?

Tell us about the project and we'll put together a detailed quote within 3 days. We generally work with general contractors.

Or email plans to bids@earthsupportcorp.com

CallEmailStart Quote